All three alarms are certified to Underwriters Laboratories standard 2034 as well as the Canadian Standards Association 6.19-01. Each alarm
carries a limited 6 year warranty from date of manufacture. Operating temperature range is from -40° to 151 ° F, relative humidity (RH) range from 15 to 95% RH.
Model 9RV is powered with a 9 volt battery.
Model 12RV-D is designed to be hardwired to separate 12 volt power supplies such as the coach battery and the engine battery.
Model 12RV-DB Battery is designed to be hardwired to separate 12 volt power supplies such as the coach battery and the engine battery. It also has a 9 volt battery that provides power if the 12 volt power supply is shutoff and provides for protection 24/7. 12RV-DB Battery Instalation/Replacement Disconnect 12 volt power to alarm before installing/replaceing 9 volt battery.Then install/replace battery and reconnect alarm 12 volt power. If the 12 volt power is not disconnected prior to battery replacement the alarm will beep every thirty seconds for ten minutes before resuming normal operation.
Both alarms are certified to Underwriters Laboratories standard 2034 marine requirements.
Each alarm carries a limited 5 year warranty from date of manufacture. Operating temperature range is from 40° to 100 ° F, relative humidity (RH) range from 15 to 95% RH.
Model 9Marine is powered with a 9 volt battery.
Model 12Marine is designed to be hardwired to separate 12 volt power supplies such as the vessel battery and the engine battery.
Model 9SIR is certified to Underwriters Laboratories standard 2034. Models 12 and 12-24SIR are certified to Underwriters Laboratories standard 2075.
Each alarm carries a limited 6 year warranty from date of manufacture. Operating temperature range is from 40° to 100 ° F, relative humidity (RH) range from 15 to 95% RH.
Model 9SIR is a residential alarm powered with a 9 volt battery.
Model 12SIR is designed to be connected to 12 volt security systems.
Model 12-24SIR is designed to be connected to security and fire systems operating at either 12 volt or 24 volt.
Ventilation Control Products
Model 24VC
Model 24VC requires 24 VAC supply voltage.
Each alarm carries a limited 5 year warranty from date of manufacture, its sensor (a replaceable module) has a lifetime of 2.5 years. Operating temperature range is from 41° to 125 ° F, relative humidity (RH) range from 10 to 95% RH.
Download Data Sheet in Acrobat® format 24/120vc
Model 120VC
Model 120VC requires 120 VAC supply voltage.
Each alarm carries a limited 5 year warranty from date of manufacture, its sensor (a replaceable module) has a lifetime of 2.5 years. Operating temperature range is from 41° to 125 ° F, relative humidity (RH) range from 10 to 95% RH.
Personal Carbon Monoxide Protection Products
Model P-1
Model P-1 is designed specifically for personal or automotive use.
Each alarm carries a limited 5 year warranty from date of manufacture. Operating temperature range is from -40° to 151 ° F, relative humidity (RH) range from 15 to 95% RH.
Download Data Sheet in Acrobat® format P-1Quantum Eye
Quantum Eye
The Quantum Eye is a multi-level Carbon Monoxide Detector. It provides a visual indication of carbon monoxide contamination. Each detector is packaged in a protective bag that when opened activates it. Once activated the minimum product lifetime is 18 months. Operating temperature range is from 41° to 100 ° F, relative humidity (RH) range from 25 to 90% RH.